1 TIP Exceptions

This chapter lists the TIP exceptions issued by the PGAU-generated TIPs and provides a possible cause and the recommended action for you to take for each message.

This chapter contains the following section:

Messages ORA-20700 to ORA-20704

ORA-20700 PGA_TIP: repeating group limits exceeded
Cause: The repetition count in a repeating group is outside its limits as defined in the PG DD for the group. The actual data being converted and exchanged through the TIP contains a count field with an invalid number.
Action: Generate the TIP with data conversion and data exchange tracing as required or rerun the application with tracing enabled. Analyze the resulting TIP and gateway server traces. Supported customers can contact Oracle Support Services for assistance.
ORA-20701 PGA_TIP: sent data length invalid cname pname, expected elen, converted clen
Cause: TIP data lengths for the, cname pname, send parameter did not correspond. One of the indicated lengths, elen or clen, is incorrect.
Action: Generate the TIP with data conversion and data exchange tracing as required or rerun the application with tracing enabled. Analyze the resulting TIP and gateway server traces. Supported customers can contact Oracle Support Services for assistance.
ORA-20702 PGA_TIP: received data length invalid cname pname, expected elen, received rlen, converted clen
Cause: TIP data lengths for the received parameter, cname pname, did not correspond. One of the indicated lengths, elen, rlen, or clen, is incorrect.
Action: Generate the TIP with data conversion and data exchange tracing as required or rerun the application with tracing enabled. Analyze the resulting TIP and gateway server traces. Supported customers can contact Oracle Support Services for assistance.
ORA-20703 PGA_TIP: pipe send error, rc = rc
Cause: The indicated error, rc, occurred on a DBMS_PIPE send call. The call was made because TIP tracing was enabled. If the value of rc equals to 1, then the 60-second pipe wait time elapsed. This is usually because the TIP trace pipe has overflowed at the inlet due to the trace message inflow exceeding 16K.
Action: Ensure that the rtrace.sql procedure is run often enough to keep the TIP trace pipe from filling and that the server output size is sufficient to hold the trace stream between rtrace calls.

See Also:

For more information, refer to Chapter 6, "Problem Determination," in Oracle Procedural Gateway for APPC User's Guide. Supported customers can contact Oracle Support Services for assistance.
ORA-20704 PGA_TIP: tranuse value cannot be shared
Cause: The tranuse value passed to a TIP function was of the type that is used for unshared TIP conversations that are associated with TIPs generated prior to release 3.4.0. This happens when a pre-3.4.0 version of a TIP is used to initiate a conversation, and its tranuse value is subsequently passed to a post-3.4.0 TIP to use both TIPs in a shared conversation.
Action: Regenerate the pre-3.4.0 TIP to cause it to pick up a new function that supports the TIP conversation sharing feature. Do not initiate the conversation with (or otherwise use) the old TIP with the new TIP. Do not call the new TIP for the active conversation. Pre-3.4.0 TIPs cannot be used with post-3.4.0 TIPs for shared conversations.